ATI A15/66 Residual Sulfite Monitor
5
O&M Manual
Rev-W (8/10)
SPECIFICATIONS
ELECTRONICS UNIT
Range: 0-2.000 or 0-20.00 PPM
Repeatability: ± 0.01 PPM
Linearity: 0.1% of F.S.
Response Time: 90% in 5 Minutes
Display: 16 character alphanumeric backlit LCD
Temperature: 0-50°C with 100 ohm Pt. RTD
Control Relays: Two SPDT relays, 5A @ 220 VAC resistive.
Programmable deadband and time delay.
Control Mode: On/Off, pulse width modulation, pulse frequency modulation
Alarm Relay: Independent SPDT relay, 5A @ 220 VAC resistive.
Programmable for actuation on high/low values or system failure.
Analog Output: Isolated 4-20 mA, 600 ohm maximum load. Programmable
output span. Output may be inverted.
Operating Conditions: 0-50° C., 0-95% R.H. non-condensing.
Power: 110/220 VAC ±10%, 50/60 Hz.
Enclosure: Panel mount standard, NEMA 4X wall mount optional.
CHEMISTRY MODULE
Sensor: Membraned SO
2
Gas Sensor
Sensor Cable: 20 feet standard, 100 feet maximum
Sample Pump: Internal Tubing Pump, 5 cc./min.
Reagent Pump: Internal Tubing Pump, 0.06 cc/min. (uses 2 tubes)
Air Supply: Diaphragm air pump with rotameter flow control
Air Stripping Chamber: Cast Acrylic
Temperature Limits: 0-40° C.
Power: 120 VAC, 60 Hz., 220 VAC, 50 Hz. Optional
Enclosure: NEMA 1
SAMPLE OVERFLOW CHAMBER
Material: Clear Acrylic
Recommended Sample Rate: 7-30 GPH (0.45 – 1.9 LPM)
Sample Inlet: ¼” I.D. Hose Barb (1/8” FNPT)
Sample Drain: ½” I.D. Hose Barb (3/8” FNPT)
Mounting Bracket: Aluminum